Honeywell flame safety relay manual






















SERIES RMA RELAY MODULE 5 —03 a Flame Failure Response Time (FFRT) depends on selection of amplifier. b Circuitry tests all electronic components in flame detection system (amplifier and detector) 12 times a minute during burner oper- ation and shuts down burner if detection system fails. c Circuitry tests flame signal amplifier 12 times a minute during burner operation and. safety relay circuit power supply keyboard display module high fire common modulate low fire high fire switch plug-in flame amplifier relay drive circuit control power test jack remote reset ddl ddl communications indicates feedback sensing of relay contact status and line volt inputs honeywell. relay. energy. modulating or. explosion. Quick Specs: FS24X QuadBand™ IR3+ Detector, Stainless Steel Encl. (2) M25 entries, CU-TR approval, T5 (Op. Temp ° to 75°C) with FSX-AR Optional Registered HART Module for FS24X Detectors Factory installed. Electronics Module with Registered HART Communication for .


degradation/welding even they are within the relays' rating. A simple solution is to place an NTC thermistor (for example, model BSM0** from EPCOS) in series between the relay and the load, to limit inrush current. Note: A RAEPoint that is factory-configured as a router does not contain relays. Terminal Block 1 (Power) Terminal Block 2. The Touchpoint™ Plus Wireless is a hybrid multi-channel controller with a built-in wireless modem that is designed for integration with RAE Systems by Honeywell MeshGuard intelligent network of connected sensors combined with traditional hard wired sensors. It is the command-and-control element of the wireless gas detection system that. Honeywell programmer and primary controls offer safety, functional capacity and other features for commercial and industrial applications. Slate. Flame Amplifier is a solid state plug-in amplifier that responds to a rectified, optical, ultraviolet or infrared signal.


RMA and EC are a flame detector relays only. Suitable primary control must be used to provide safe-start check, safety lockout, load switching and other functions required in flame safeguard systems. Three LEDs to indicate power, flame and alarm. Access for external electrical voltage checks. Nonvolatile memory. Shutter drive output. 1 —2 SERIES RMA,B,C Relay Module The Honeywell RM is a microprocessor based integrated burner control for automatically fired gas, oil or combination fuel single-burner appli-. The Relay Modules, Flame Amplifiers and Flame De-tectors covered by this safety manual are suitable for use in both high and low demand mode of operation Safety Integrity Functions (SIF) up to SIL 3 in simplex (1oo1) configurations. The achieved SIL for a particular SIF needs to be verified by.

0コメント

  • 1000 / 1000